Product
description
|
|
Description
|
GREYHOUND
Fast Ethernet Media Module
|
Port type and quantity
|
8
x ports in total ; 2 x FE MM, SC ; 2 x FE MM, SC ; 2 x FE MM, SC ; 2 x FE MM,
SC
|
Network
size - length of cable
|
|
Multimode fiber (MM) 50/125 µm
|
port
1 and 3: 0 - 5000 m, 8 dB Link Budget at 1300 nm, A = 1 dB/km, 3 dB reserve,
B = 800 MHz x km; port 5 and 7: 0 - 5000 m, 8 dB Link Budget at 1300 nm, A =
1 dB/km, 3 dB reserve, B = 800 MHz x km; port 2 and 4: 0 - 5000 m, 8 dB Link
Budget at 1300 nm, A = 1 dB/km, 3 dB reserve, B = 800 MHz x km; port 6 and 8:
0 - 5000 m, 8 dB Link Budget at 1300 nm, A = 1 dB/km, 3 dB reserve, B = 800
MHz x km;
|
Multimode fiber (MM) 62.5/125 µm
|
port
1 and 3: 0 - 4000 m, 11 dB Link Budget at 1300 nm, A = 1 dB/km, 3 dB reserve,
B = 500 MHz x km; port 5 and 7: 0 - 4000 m, 11 dB Link Budget at 1300 nm, A =
1 dB/km, 3 dB reserve, B = 500 MHz x km; port 2 and 4: 0 - 4000 m, 11 dB Link
Budget at 1300 nm, A = 1 dB/km, 3 dB reserve, B = 500 MHz x km; port 6 and 8:
0 - 4000 m, 11 dB Link Budget at 1300 nm, A = 1 dB/km, 3 dB reserve, B = 500
MHz x km;
|
Power
requirements
|
|
Operating Voltage
|
power
supply via GREYHOUND switch
|
Power consumption
|
9
W
|
Power output in BTU (IT)/h
|
31
|
Ambient
conditions
|
|
MTBF (Telecordia SR-332 Issue 3) @ 25°C
|
1
179 558 h
|
Operating temperature
|
0-+60
°C
|
Storage/transport temperature
|
-40-+70
°C
|
Relative humidity (non-condensing)
|
5-95
%
|
Mechanical
construction
|
|
Weight
|
520
g
|
Protection class
|
IP30
|
Mechanical
stability
|
|
IEC 60068-2-6 vibration
|
1
mm, 2 Hz-13.2 Hz, 90 min.; 0.7 g, 13.2 Hz-100 Hz, 90 min.; 3.5 mm, 3 Hz-9 Hz,
10 cycles, 1 octave/min.; 1 g, 9 Hz-150 Hz, 10 cycles, 1 octave/min
|
IEC 60068-2-27 shock
|
15
g, 11 ms duration, 18 shocks
|
EMC
interference immunity
|
|
EN 61000-4-2 electrostatic discharge (ESD)
|
8
kV contact discharge, 15 kV air discharge
|
EN 61000-4-3 electromagnetic field
|
35
V/m (80-2700 MHz); 1 kHz, 80% AM
|
EN 61000-4-4 fast transients (burst)
|
4
kV power line, 4 kV data line
|
EN 61000-4-5 surge voltage
|
power
line: 2 kV (line/earth), 1 kV (line/line); data line: 1 kV; IEEE1613: power
line 5kV (line/earth)
|
EN 61000-4-6 Conducted Immunity
|
3
V (10 kHz-150 kHz), 10 V (150 kHz-80 MHz)
|
EN 61000-4-16 mains frequency voltage
|
30
V, 50 Hz continous; 300 V, 50 Hz 1 s
|
EMC
emitted immunity
|
|
EN 55022
|
EN
55032 Class A
|
FCC CFR47 Part 15
|
FCC
47CFR Part 15, Class A
|
Approvals
|
|
Basis Standard
|
CE,
FCC, EN61131
|
Safety of industrial control equipment
|
EN60950,
cUL60950
|
Shipbuilding
|
DNV
|
Substation
|
IEC61850,
IEEE1613
|
Scope
of delivery and accessories
|
|
Scope of delivery
|
Device,