Power supply GREYHOUND Switch only 60 to 250 V DC and 110 to 240 V AC, 35W

Power supply GREYHOUND Switch only

60 to 250 V DC and 110 to 240 V AC, 35W

Varunummer: GPS1-KEUYHH
Product description
DescriptionPower supply GREYHOUND Switch only
Power requirements
Operating Voltage60 to 250 V DC and 110 to 240 V AC
Power consumption2.5 W
Power output in BTU (IT)/h9
Ambient conditions
MTBF (MIL-HDBK 217F: Gb 25 ºC)757 498 h
Operating temperature-40-+70 °C
NoteIEC 60068-2-2 Dry Heat Test +85°C 16 Hours
Storage/transport temperature-40-+85 °C
Relative humidity (non-condensing)5-95 %
Protective paint on PCBYes (conformal coating)
Mechanical construction
Weight710 g
Protection classIP30
Mechanical stability
IEC 60068-2-6 vibration1 mm, 2 Hz-13.2 Hz, 90 min.; 0.7 g, 13.2 Hz-100 Hz, 90 min.; 3.5 mm, 3 Hz-9 Hz, 10 cycles, 1 octave/min.; 1 g, 9 Hz-150 Hz, 10 cycles, 1 octave/min
IEC 60068-2-27 shock15 g, 11 ms duration, 18 shocks
EMC interference immunity
EN 61000-4-2 electrostatic discharge (ESD)8 kV contact discharge, 15 kV air discharge
EN 61000-4-3 electromagnetic field35 V/m (80-2700 MHz); 1 kHz, 80% AM
EN 61000-4-4 fast transients (burst)4 kV power line, 4 kV data line
EN 61000-4-5 surge voltagepower line: 2 kV (line/earth), 1 kV (line/line); data line: 1 kV; IEEE1613: power line 5kV (line/earth)
EN 61000-4-6 Conducted Immunity3 V (10 kHz-150 kHz), 10 V (150 kHz-80 MHz)
EN 61000-4-16 mains frequency voltage30 V, 50 Hz continous; 300 V, 50 Hz 1 s
EMC emitted immunity
EN 55032EN 55032 Class A
Approvals
Basis StandardCE, FCC, EN61131
Safety of industrial control equipmentEN60950, cUL60950
ShipbuildingDNV
Reliability
Guarantee60 months (please refer to the terms of guarantee for detailed information)
Scope of delivery and accessories
AccessoriesPower Cord, 942 000-001
Scope of deliveryDevice, General safety instructions